Ramset fasteners may be specified by their type or catalog number to satisfy fastening requirements.
PIN SPECIFICATIONS
APPROVALS/LISTINGS
| Made from AISI 1060-1065 steel. Austempered to a core hardness of 52-56 Rc
| Typical tensile strength: 270,000 psi
| Typical shear strength: 162,000 psi
| Standard finishes
-Proprietary black
-Mechanical zinc plate to a minimum thickness of .0002 meets requirements of ASTM B695
-Electroplated zinc with yellow chromate
| ICC Evaluation Service, Inc. #ER-1147 Sill Plate
#ESR-1799 Powder Pins & Clips (formerly ER-1639)
#ER-3618 Ladd
#ER-5001 TrakFast Pins
#ERS-1955 T3 Fasteners
| City of Los Angeles #RR-22668 Powder Pins
#RR-24279 Ladd
#RR-25264 TrakFast Pins

Performance Tables

COLLATED GAS FASTENERS IN CONCRETE (TRAKFAST, T2 AND T3)
PART
NUMBER
SERIES
SHANK
DIAMETER
(INCH)
MINIMUM
PENETRATION
(INCH)
INSTALLED IN STONE AGGREGATE CONCRETE
CONCRETE COMPRESSIVE STRENGTH PSI

ALLOWABLE LOAD Ultimate Load
2000 PSI
3000 PSI
4000 PSI
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
FPP—
Straight
Shank
0.109
5/8
60  434
55 546
55  453
75  615
55  472
 95  685
3/4
60  595
80  650
55  583
95  699
55  571
115  749
FPP—
Step
Shank
0.104/
0.118
3/4
---  ---
---  ---
---  ---
---  ---
51  256
83  418
T3
Straight
Shank
0.125
5/8
83  414
109 611
---  ---
---  ---
78  426
 80  574
3/4
107  541
156  855
---  ---
---  ---
104  593
195  977

COLLATED GAS FASTENERS IN CONCRETE (TRAKFAST, T2 AND T3)
PART
NUMBER
SERIES
SHANK
DIAMETER
(INCH)
MINIMUM
PENETRATION
(INCH)
INSTALLED IN STONE AGGREGATE CONCRETE
CONCRETE COMPRESSIVE STRENGTH PSI

ALLOWABLE LOAD Ultimate Load
3000 PSI
LIGHT WEIGHT CONCRETE
3000 PSI
LIGHT WEIGHT
CONCRETE WITH
METAL DECK
HOLLOW CONCRETE
MASONRY UNITS (CMU)
ANY LOCATION
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
FPP—
Straight
Shank
0.109
5/8
35  234
55 403
30  239
205  1025
35  347
 50  435
3/4
80  630
115  756
40  330
100  1284
---  ---
---  ---
FPP—
Step
Shank
0.104/
0.118
3/4
---  ---
---  ---
---  ---
---  ---
36  184
58  290
T3
Straight
Shank
0.125
5/8
84  418
108 540
72  361
242  1210
20  243
 34  264
3/4
108  540
173  864
93  470
288  1442
---  ---
---  ---
Note 1: ALLOWABLE loads are shown in the LARGE BOLD font, Ultimate loads are shown in smaller italic font.
Note 2: Testing conducted in accordance with ICC AC70 & ASTM E1190.
Note 3: Safety factors are based on coefficient of variation. In accordance with ICC AC70, the safety factor will be no less than 5.
Note 4: Values shown in concrete are for the fastener only. Connected members must be investigated separately.
Note 5: Cyclic, fatigue, shock loads, and other design criteria may require a different safety factor.
Note 6: Job site testing may be required to determine actual job site values.
Note 7: Minimum edge distance in concrete is 3 inches unless otherwise approved.
Note 8: For SI: 1 lbf = 4.448 N, 1 inch = 25.4 mm, 1 ksi = 6.89MPa
Note 9: T3 straight shank allowable tension value in face shell of hollow CMU is 133 lbs.
 

Click here to view tables in metric.

Back to the top

FASTENERS IN CONCRETE
FASTENER
PART
NUMBER
SHANK
DIA.
(INCH)
MINIMUM
PENETRATION
(INCH)
INSTALLED IN STONE AGGREGATE CONCRETE
CONCRETE COMPRESSIVE STRENGTH

ALLOWABLE LOAD Ultimate Load
HOLLOW BLOCK
Grade N, Type 1
4000 PSI
6000 PSI
3000 PSI
LIGHT WEIGHT
LOWER FLUTE
FACE SHELL
Min 1-1/4"
face thickness
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
GAS ASSEMBLIES
MP034TH
M034
M100
BR2
0.125
5/8
78
426
80
574
62
308
---
---
72
361
242
1210
133
691
---
---
3/4
104
593
195
977
132
658
206
1057
93
470
288
1442
84
444
87
466
14STUD
.125
5/8
91
454
---
---
57
373
---
---
---
---
---
---
---
---
---
---
M034BB
0.104/
.118
3/4
51
256
83
418
---
---
---
---
---
---
---
---
36
184
58
290
34CLIP
0.104/
.118
5/8
62
310
---
---
106
528
---
---
44
220
---
---
---
---
---
---
38HSMP034
12HSMP034
34HSMP034
10HSMP034
114HSMP034
14TRHMP034
38TRHMP034
TSHMP034
12CCMP034L
34CCMP034L
0.104/
.125
5/8
60
357
117
587
107
533
191
957
54
269
230
1150
71
357
123
613
POWDER ASSEMBLIES
M100BB
38HSSS10
12HSSS10
34HSSS10
10HSSS10
TSHSS10
12CCSS10L
34CCSS10L

14TRHSS10
38TRHSS10
0.125/
.150
3/4
107
559
213
1067
161
803
248
1240
96
478
231
1156
102
512
166
831
Note 1: ALLOWABLE loads are shown in the LARGE BOLD font, Ultimate loads are shown in smaller italic font.
Note 2: Testing conducted in accordance with ICC AC70 & ASTM E1190.
Note 3: Safety factors are based on coefficient of variation. In accordance with ICC AC70, the safety factor will be no less than 5.
Note 4: Values shown in concrete are for fastener only. Connected members must be investigated separately.
Note 5: Cyclic, fatigue, shock loads and other design criteria may require a different safety factor.
Note 6: Job-site testing may be required to determine actual job site values.
Note 7: Minimum edge distance is 3 inches unless otherwise approved. In hollow block applications, no more than one fastener per cell
Note 8: For SI: 1 lbf = 4.448 N, 1 inch = 25.4 mm, 1 ksi = 6.89MPa
  Click here to view tables in metric.
Back to the top

GAS FASTENERS IN STEEL
PART
NUMBER
SHANK
DIA.
(INCH)
TYPE OF
SHANK
INSTALLED IN STONE AGGREGATE CONCRETE
CONCRETE COMPRESSIVE STRENGTH

ALLOWABLE LOAD Ultimate Load
3/16 (.1875)
1/4 (.250)
3/8 (.375)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
TENSION
(LBS)
SHEAR
(LBS)
FPP012
0.109
SMOOTH
200
1047
315
1570
230
1220
305
1526
210
10487
215
10767
M012
FPP012S
0.104/
.118
SMOOTH
---
---
---
---
148
744
157
787
166
8327
157
7877
T3012
0.125
SMOOTH
63
676
162
1356
239
1285
211
1417
113
9148
197
13278
      INSTALLED IN ASTM A 572 GRADE 50 STEEL
STEEL THICKNESS INCHES
T3012
0.125
SMOOTH
102
733
222
1682
147
950
119
973
147
8569
112
10149
**Fasteners shall have minimum 0.32-inch penetration when installed into 3/8-inch thick steel.
Note 1: ALLOWABLE loads are shown in the LARGE BOLD font, Ultimate loads are shown in smaller italic font.
Note 2: Testing conducted in accordance with ICC AC70 & ASTM E1190.
Note 3: Safety factors are based on coefficient of variation. In accordance with ICC AC70, the safety factor will be no less than 5.
Note 4: Cyclic, fatigue, shock loads and other design criteria may require a different safety factor.
Note 5: Job-site testing may be required to determine actual job site values.
Note 6: Values shown are for fastenings that have the entire pointed end of the fastener driven through the steel plate; except as noted below.
Note 7: Fastener penetration is .31" minimum.
Note 8: Fastener penetration is .29" minimum.
Note 9: Fastener penetration is .27" minimum.
Note 10: For SI: 1 lbf = 4.448 N, 1 inch = 25.4 mm, 1 ksi = 6.89MPa
  Click here to view tables in metric.
Back to the top
Click here to download these tables in pdf format.

Return to Ramset Gas Fastening Systems

Fasteners | Performance/Submittals | Accessories | Approval and Listings